Solution3.4InstallationandOperationManual
31

Clearancestoheatsensitivematerialsandfloorprotection
7.3 FLOORPROTECTOR
If the wood fire is to be installed on top of a combustible floor, it must be guarded by a non
combustiblematerialasshownonthedottedlineareaoftheabovefigures.Installa850mm(W)x
1215mm(D)floorprotectionof6mmofthicknesswiththermalconductivity of0.8m
2
K/Wper4
mmthick.
FLOORPROTECTOR*
FROMDOOROPENING
D 615mm
E 200mm**
*Cement fibre sheet or similar. No protection is required if the unit is installed on a non
combustiblefloor(ex:concrete).
**Thefloorprotectorshallextendnotlessthan200mmfromeachsideofanyashremovalor
fuelloadingopeningsunlessthefloorprotectorformsanabutmentwith
awallorheatshieldat
alesserdistance.